Note: The file format here is the same as in my earlier article Do it better with awk 1.
Today I was able to meet Bryan of Guru Labs. During our conversation he posed the following question. “Find the 3rd field in a file consisting of space operated fields, the first being an ip address, with in the range 192.168.1-2.1-255. There maybe lines in the file containing invalid ip addresses.”
I used grep to find the lines and then used awk to find the field. For example:
$ egrep '^192\.168\.[1-2]\.([0-9]|[1-9][0-9]|1[0-9]{2}|2[0-4][0-9]|2[0-5]{2})' access_log | awk '{print $(NF-1)}'
200
304
304
...
He pointed out that, while this works, there is no reason to invoke grep. He is certainly correct, there is no reason to invoke grep. Indeed, awk is all powerful! The default usage of awk is:
awk 'pattern { command }'
In its most common and simple usage, to print a field deliminated by spaces:
awk '{print $3}'
You are specifying no pattern, which matches every line. When solving the problem posed by Bryan, simply specify the pattern and eliminate grep from the pipe line. Here is the previous pipeline, using only awk:
$ awk '/^192\.168\.[1-2]\.([0-9]|[1-9][0-9]|1[0-9]{2}|2[0-4][0-9]|2[0-5]{2})/ {print $(NF-1)}' access_log
200
304
304
...
Awk has some extremely powerful selecting operators. Here I am using the ~ operator to match the third field from the right (resource), to ^/man, and printing the matched field:
$ awk '$(NF-3) ~ /^\/man/ {print $(NF-3)}' access_log
/man/cmd/info
/man/cmd/Mail
/man/s/Z
/man/cmd/mv
...
This invocation uses the !~ operator, to match lines where the resource does not match the pattern ^/man:
$ awk '$(NF-3) !~ /^\/man/ {print $(NF-3)}' access_log
/feed/
/feed
/robots.txt
/10-linux-commands-youve-never-used.html
...
Here I am selecting lines where the response code $(NF-1) is greater than 200, but less than 400 and then printing the resource and response code. I use awk’s boolean “and” operator && to perform this operation:
$ awk '$(NF-1) >= 200 && $(NF-1) <= 399 {print $(NF-3), $(NF-1)}' access_log
/man/cmd/info 200
/feed/ 304
/feed 304
...
The following example uses the boolean “or” operator || to print lines where there resource matches ^/feed or ^/sitemap.
$ awk '$(NF-3) ~ /^\/feed/ || $(NF-3) ~ /^\/sitemap/ {print $0}' access_log
192.168.1.2 - - [01/Jan/2008:00:00:31 -0600] "GET /feed/ HTTP/1.1" 304 -
192.168.1.3 - - [01/Jan/2008:00:01:09 -0600] "GET /feed HTTP/1.1" 304 -
...
1.1、系统概述
FAS3050和FAS3050c是NetApp统一网络存储的FAS3000系列的产品,专为满足高端存储的应用需求而设计。FAS3000 系列系统非常适合用于企业应用基础设施,比如数据库、电子邮件/消息收发、主目录合并和灾难恢复解决方案。FAS3000系列通过对NFS、CIFS、HTTP、iSCSI、FCP等协议的支持,可同时满足NAS和SAN的构架。
FAS3000 系统进一步提高针对小数据卷的磁盘性能,使用 FlexVol 技术可以降低存储管理成本,将客户的存储利用率提高 50%。结合新的 SATA 存储选件,主要存储成本可以减少一半以上。
主要特点:
高可靠性,超过99.998%的数据可用性,减少了代价高昂的宕机时间,最大限度地保障了对关键数据的访问。FAS3050C可提供集群的双活动(Active-Active)配置支持。
高性能,在多用户多协议环境中提供了业界领先的吞吐量和响应时间。
高扩展性,实现了即时的可扩展性,能够在一套单一系统或是多Filer的配置环境中支持数千名用户和数千项事务处理以及数万亿字节的信息。
简单,易于安装、操作与升级。
灵活,利用现有的以太网或是光纤通道基础设施,能够同时满足 NAS、iSCSI SAN 以及光纤通道 SAN 等多方面的存储需求。
可同时支持FC硬盘和SATA硬盘,以满足不同应用的需求。
1.2、硬件特性
FAS3050和FAS3050c系统图示如下:
FAS3050系统包括:
2*2.8GHz Intel Xeon处理器,支持超线程功能
4GB DDR-DRAM系统内存
512MB NVRAM-5
远程管理模块(Remote LAN Module - 选配)
3个PCI-X扩展槽
内置4个10/100/1000Base-T千兆以太网接口,最多可提供12个千兆以太网接口
内置4个光纤通道(FC)接口,最多可提供10个FC接口
最多336个磁盘,支持FC硬盘和SATA硬盘混合使用
最多84TB的裸盘容量
最大单卷容量17.6TB
FAS3050c系统包括:
4x 2.8GHz Intel Xeon处理器,支持超线程功能
8GB DDR-DRAM系统内存
1GB NVRAM-5
远程管理模块(Remote LAN Module - 选配)
6个PCI-X扩展槽
内置8个10/100/1000Base-T千兆以太网接口,最多可提供24个千兆以太网接口
内置8个光纤通道(FC)接口,最多可提供20个FC接口
最多336个磁盘,支持FC硬盘和SATA硬盘混合使用
最多84TB的裸盘容量
最大单卷容量17.6TB
1.3、系统性能
| 系统性能 | FAS3050 | FAS3050c |
1.4、产品亮点
|
产品亮点 |
|
| 操作系统 | Network Appliance™ Data ONTAP™ 7G 软件 |
| 标准软件功能 | 集成的自动 RAID 管理器、Snapshot™、Fast Boot、电子邮件提示、NIS、DNS、SNMP、FilerView®、FlexVol™、NDMP、LDAP |
| 网络协议支持 | Microsoft® CIFS、NFS V2/V3/V4(采用 UDP 或 TCP)、HTTP 1.0、HTTP 1.1 虚拟主机、FTP |
| SAN 协议支持 | FCP;iSCSI;光纤网络存储和直连式存储 |
| 获得许可的软件产品 | FlexClone™、MultiStore™、Clustered Failover、SnapMirror®、SnapRestore®、SnapDrive™、SnapManager® for Microsoft Exchange、SnapManager for Microsoft SQL Server、SnapVault™、LockVault™、SnapLock™ Compliance、SnapLock™ Enterprise、SyncMirror™、MetroCluster、DataFabric® Manager、ApplianceWatch™ for HP Openview、Tivoli |
| 标准硬件功能 | 10/100/1000 Base-T 双工以太网网卡、光纤通道端口板、远程 LAN 管理模块(选件)、(1) 内置 LVD SCSI 端口、诊断用 LED/LCD、Compact Flash、可热插拔的冗余散热风扇、可热插拔的冗余电源、19″ 架装式机箱、220V 42U 19″ 系统机柜选件 |
| 默认/最小/最大 RAID 组大小 | RAID-4(单奇偶校验) - FC- 数据/奇偶校验:7+1 (13+1);SATA- 数据/奇偶校验:7+1 (7+1)RAID-DP(双奇偶校验) - FC- 数据/奇偶校验:14+2 (26+2);SATA- 数据/奇偶校验:12+2 (14+2) |
| 支持的磁盘架(光纤通道) | DS14、DS14mk2 FC、DS14mk2 AT |
| 支持的磁盘驱动器容量 | 72/144/300GB FC、250GB ATA |
1.5、系统规格
|
系统规格 |
FAS3050 |
FAS3050C |
| 应用环境 | 大型企业和技术计算 | 大型企业和技术计算 |
| 存储网络支持 | FC SAN、IP SAN 和 NAS | FC SAN、IP SAN 和 NAS |
| 最大原始容量 最大磁盘驱动器数 最大光纤通道环路数 每个 FC 环路最大驱动器数 |
84TB 336 4 84 |
84TB 336 8 84 |
| 最大卷大小/合计大小 | 17.6TB | 17.6TB |
| ECC 内存 | 4GB | 8GB |
| 非易失性内存 | 512MB | 1GB |
| PCI-X 扩展插槽 | 3 | 6 |
| 配置 GbE 端口数 | 4 | 8 |
| 配置 2Gb 光纤通道端口数(可根据存储系统连接的发起端或主机连接的目标端进行配置) | 4 | 8 |
| 可选网络连接 四 GbE(铜介质)卡数 双 GbE(铜介质或光纤)卡数 |
最多 2 个 最多 3 个 |
最多 4 个 最多 6 个 |
| 双 FC 磁盘适配器数 | 最多 3 个 | 最多 6 个 |
| 单 FC 磁盘适配器数(旧磁盘架使用铜缆) | 不适用 | 不适用 |
| 集群容错功能 | 可选 | 标准 |
| 双 FC、单 FC 或 LVD SCSI 磁带适配器 | 最多 3 个 | 最多 6 个 |
1.6、系统环境规范
|
系统环境规范 |
FAS3050 |
FAS3050C |
|
交流电源/电流 |
88 至 246VAC/9.5 至 3.2A |
88 至 246/19 至 6.4A |
| 额定散热量 | 853 Btu/hr | 1706 Btu/hr |
| 重量 | 配置齐全情况下 34 kg (75 lb) |
配置齐全情况下 68 kg (150 lb) |
| 高度 | 13 cm (5.12″) 3U EIA |
26 cm (10.6″) 6U EIA |
| 宽度 | 44.9 cm (17.7″) | |
| 深度 | 61 cm (24″)(不带电缆管理架) 76.2 cm (30″)(带电缆管理架) |
|
| 工作温度 | 10°C 至 40°C(50°F 至 104°F) | |
| 存放温度 | -40°C 至 65°C(-40°F 至 149°F) | |
| 工作和存放相对湿度 | 5% 至 95% 相对湿度 | |
| 工作噪声 | <正常工作条件下 54 dBA 声压 (LpA)。正常工作条件包括活动系统在海平面 22°C 室温下运行。 | |
| 最小机柜间隙 | 正面 25.4 cm (10″),背面 30.5 cm (12″) | |
| 最小维修空间 | 正面 76.2 cm (30″),背面 76.2 cm (30″) | |
| 海拔高度 | 最大 10,000 ft | |
1.7、FAS3000系列 FC交换机支持-磁带/SAN
|
FAS3000 系列 FC 交换机支持 - 磁带/SAN |
|
|
供应商 |
型号 |
| Brocade | Silkworm 2400/2800(仅用于 TapeSAN) |
| Brocade | Silkworm 3200/3250/3800/3850/3900/4100/12000/24000 |
| McData | ES 3016/3032 |
| McData | Intrepid 6064/6140/ED 5000 |
| McData | Sphereon 3216/3232/4500 |
| Cisco | MDS 9120、9140、9216A、9216i、9506、9509 |
1.8、存储子系统规格
|
存储子系统规格 |
|
|
磁盘驱动器存储架 |
DiskShelf14 系列 - DS14、DS14mk2 FC 和 DS14mk2AT;每个存储架均带有 14 个 FC 和 SATA 磁盘驱动器专用短插槽 |
| 磁盘驱动器存储架接口 | 基于 PCI 的光纤通道仲裁环路 (FC-AL) |
| DiskShelf14 接口 | 双冗余回路阻抗电路 (LRC) 模块或者冗余电子交换集线器(ESH 和 ESH2)模块 |
| 电源/散热风扇 | 可热插拔的双组冗余集成电源/风扇 (220V/110V) |
| 交流电源/最大电流 | 100 至 120 VAC/4.4A;200 至 240 VAC/2.3A |
| 工作温度和相对湿度 | 10°C 到 40°C(50°F 至 104°F);相对湿度 10% 到 95%,非凝结 |
| 存放温度和相对湿度 | -40°C 到 65°C(-40°F 至 149°F);相对湿度 10% 到 95%,非凝结 |
| 额定散热量 | 1,215 Btu/hr(机架满载情况下) |
| 工作噪声 | 23°C 时距离 1m 处 49 dBA |
| 尺寸(高/宽/深) | 3U EIA (5.25″, 13.3 cm)/可安装在 19″ IEC 机架上(17.6″,44.7 cm)/20″ (50.85 cm) |
| 重量 | 满载情况下 77 lb (35 kg) |
1.9、NETAPP系统机柜
|
NetApp 系统机柜 |
|
|
包含两组双 16A、Zero U 型配电架 (PDU) |
可以容纳 1 系统控制器和 13 个磁盘架,或者可以容纳 2 系统控制器和 12 个磁盘架,或者仅容纳 14 个磁盘架 |
| 交流电源 | 200 至 240VAC |
| 电流 | 总共 32A - 带有 NEMA L6-20 或 IEC 309 或 Australia AS/NZ53123-20 插头的两组冗余双 16A 电缆;或者总共 24A - 带有 NEMA L6-30 或 IEC 309 插头的两个冗余 24A 电缆。 |
| 尺寸(高/宽/深) | 78.75″ (200 cm)/23.6″ (60 cm)/37.4″ (95 cm) |
| 最小间隙 | 前后各 48″ (122 cm) |
| 运输高度 | 90.6″ (230 cm) |
| 重量(空载) | 275 lb (125 kg) |
1.10、法规
|
法规 |
NetApp FAS3000 系列存储设备,DiskShelf14 |
|
Filer 安全性 |
EN 60950:2002、CE、CSA 60950 和 NRTL (UL) CB(各种类似国家标准)、EN60825-1:1994、IRAM、GOST-R |
| 磁盘架安全性 | UL/C-UL;CE |
| 辐射 | FCC Class A、EN 55022:1998、EN 61000-3-2、EN 61000-3-3、CE、BSMI、AS/NZ 3548、VCCI |
| 抗扰度 | EN 55024:1998 |
1.11、对FAS3000系统磁带机的支持
|
FAS3000 系列磁带机的支持 |
|
|
合格的磁带设备 |
接口 |
|
Exabyte 8900 (Mammoth-1)、Mammoth-2 |
LVD SCSI. |
| HP Ultrium (LTO) | LVD SCSI |
| IBM 3590B、3590E | FC |
| IBM ULT3580-TDI (LTO) Ultrium-TDI (LTO) | LVD SCSI 或 FC |
| Quantum DLT 7000 | SE SCSI |
| Quantum DLT 8000、DLT-1、SDLT 220、SDLT 320 | LVD SCSI SCSI |
| Seagate Ultrium (LTO) | LVD SCSI |
| Sony AIT-1、AIT-2、AIT-3 | LVD SCSI |
| Sony GY 8240 (DTF2) | FC |
| STK 9840、9840B、9940 | FC |
FC = 光纤通道;LVD = 低压差分;SE = 单端;SE 和 LVD 不能在适
1.1、系统概述
FAS3020和FAS3020c是NetApp统一网络存储的FAS3000系列的产品,专为满足中高端存储的应用需求而设计。FAS3000 系列系统非常适合用于企业应用基础设施,比如数据库、电子邮件/消息收发、主目录合并和灾难恢复解决方案。FAS3000系列通过对NFS、CIFS、HTTP、iSCSI、FCP等协议的支持,可同时满足NAS和SAN的构架。
FAS3000 系统进一步提高针对小数据卷的磁盘性能,使用 FlexVol 技术可以降低存储管理成本,将客户的存储利用率提高 50%。结合新的 SATA 存储选件,主要存储成本可以减少一半以上。
主要特点:
高可靠性,超过99.998%的数据可用性,减少了代价高昂的宕机时间,最大限度地保障了对关键数据的访问。FAS3020C可提供集群的双活动(Active-Active)配置支持。
高性能,在多用户多协议环境中提供了业界领先的吞吐量和响应时间。
高扩展性,实现了即时的可扩展性,能够在一套单一系统或是多Filer的配置环境中支持数千名用户和数千项事务处理以及数万亿字节的信息。
简单,易于安装、操作与升级。
灵活,利用现有的以太网或是光纤通道基础设施,能够同时满足 NAS、iSCSI SAN 以及光纤通道 SAN 等多方面的存储需求。
可同时支持FC硬盘和SATA硬盘,以满足不同应用的需求。
1.2、硬件特性
FAS3020和FAS3020c系统图示如下:
FAS3020系统包括:
2.8GHz Intel Xeon处理器,支持超线程功能
2GB DDR-DRAM系统内存
512MB NVRAM-5
远程管理模块(Remote LAN Module - 选配)
3个PCI-X扩展槽
内置4个10/100/1000Base-T千兆以太网接口,最多可提供12个千兆以太网接口
内置4个光纤通道(FC)接口,最多可提供10个FC接口
最多168个磁盘,支持FC硬盘和SATA硬盘混合使用
最多50TB的裸盘容量
最大单卷容量17.6TB
FAS3020c系统包括:
2x 2.8GHz Intel Xeon处理器,支持超线程功能
4GB DDR-DRAM系统内存
1GB NVRAM-5
远程管理模块(Remote LAN Module - 选配)
6个PCI-X扩展槽
内置8个10/100/1000Base-T千兆以太网接口,最多可提供24个千兆以太网接口
内置8个光纤通道(FC)接口,最多可提供20个FC接口
最多168个磁盘,支持FC硬盘和SATA硬盘混合使用
最多50TB的裸盘容量
最大单卷容量17.6TB
1.3、系统性能
| 系统性能 | FAS3020 | FAS3020c |
1.4、产品亮点
|
产品亮点 |
|
| 操作系统 | Network Appliance™ Data ONTAP™ 7G 软件 |
| 标准软件功能 | 集成的自动 RAID 管理器、Snapshot™、Fast Boot、电子邮件提示、NIS、DNS、SNMP、FilerView®、FlexVol™、NDMP、LDAP |
| 网络协议支持 | Microsoft® CIFS、NFS V2/V3/V4(采用 UDP 或 TCP)、HTTP 1.0、HTTP 1.1 虚拟主机、FTP |
| SAN 协议支持 | FCP;iSCSI;光纤网络存储和直连式存储 |
| 获得许可的软件产品 | FlexClone™、MultiStore™、Clustered Failover、SnapMirror®、SnapRestore®、SnapDrive™、SnapManager® for Microsoft Exchange、SnapManager for Microsoft SQL Server、SnapVault™、LockVault™、SnapLock™ Compliance、SnapLock™ Enterprise、SyncMirror™、MetroCluster、DataFabric® Manager、ApplianceWatch™ for HP Openview、Tivoli |
| 标准硬件功能 | 10/100/1000 Base-T 双工以太网网卡、光纤通道端口板、远程 LAN 管理模块(选件)、(1) 内置 LVD SCSI 端口、诊断用 LED/LCD、Compact Flash、可热插拔的冗余散热风扇、可热插拔的冗余电源、19″ 架装式机箱、220V 42U 19″ 系统机柜选件 |
| 默认/最小/最大 RAID 组大小 | RAID-4(单奇偶校验) - FC- 数据/奇偶校验:7+1 (13+1);SATA- 数据/奇偶校验:7+1 (7+1)RAID-DP(双奇偶校验) - FC- 数据/奇偶校验:14+2 (26+2);SATA- 数据/奇偶校验:12+2 (14+2) |
| 支持的磁盘架(光纤通道) | DS14、DS14mk2 FC、DS14mk2 AT |
| 支持的磁盘驱动器容量 | 72/144/300GB FC、250GB ATA |
1.5、系统规格
|
系统规格 |
FAS3020 |
FAS3020C |
| 应用环境 | 企业应用基础设施 | 企业应用基础设施 |
| 存储网络支持 | FC SAN、IP SAN 和 NAS | FC SAN、IP SAN 和 NAS |
| 最大原始容量 最大磁盘驱动器数 最大光纤通道环路数 每个 FC 环路最大驱动器数 |
50TB 168 4 84 |
50TB 168 8 84 |
| 最大卷大小/合计大小 | 17.6TB | 17.6TB |
| ECC 内存 | 2GB | 4GB |
| 非易失性内存 | 512MB | 1GB |
| PCI-X 扩展插槽 | 3 | 6 |
| 配置 GbE 端口数 | 4 | 8 |
| 配置 2Gb 光纤通道端口数(可根据存储系统连接的发起端或主机连接的目标端进行配置) | 4 | 8 |
| 可选网络连接 四 GbE(铜介质)卡数 双 GbE(铜介质或光纤)卡数 |
最多 2 个 最多 3 个 |
最多 4 个 最多 6 个 |
| 双 FC 磁盘适配器数 | 最多 3 个 | 最多 6 个 |
| 单 FC 磁盘适配器数(旧磁盘架使用铜缆) | 不适用 | 不适用 |
| 集群容错功能 | 可选 | 标准 |
| 双 FC、单 FC 或 LVD SCSI 磁带适配器 | 最多 3 个 | 最多 6 个 |
1.6、系统环境规范
|
系统环境规范 |
FAS3020 |
FAS3020C |
|
交流电源/电流 |
88 至 246VAC/9.5 至 3.2A |
88 至 246/19 至 6.4A |
| 额定散热量 | 853 Btu/hr | 1706 Btu/hr |
| 重量 | 配置齐全情况下 34 kg (75 lb) |
配置齐全情况下 68 kg (150 lb) |
| 高度 | 13 cm (5.12″) 3U EIA |
26 cm (10.6″) 6U EIA |
| 宽度 | 44.9 cm (17.7″) | |
| 深度 | 61 cm (24″)(不带电缆管理架) 76.2 cm (30″)(带电缆管理架) |
|
| 工作温度 | 10°C 至 40°C(50°F 至 104°F) | |
| 存放温度 | -40°C 至 65°C(-40°F 至 149°F) | |
| 工作和存放相对湿度 | 5% 至 95% 相对湿度 | |
| 工作噪声 | <正常工作条件下 54 dBA 声压 (LpA)。正常工作条件包括活动系统在海平面 22°C 室温下运行。 | |
| 最小机柜间隙 | 正面 25.4 cm (10″),背面 30.5 cm (12″) | |
| 最小维修空间 | 正面 76.2 cm (30″),背面 76.2 cm (30″) | |
| 海拔高度 | 最大 10,000 ft | |
1.7、FAS3000系列 FC交换机支持-磁带/SAN
|
FAS3000 系列 FC 交换机支持 - 磁带/SAN |
|
|
供应商 |
型号 |
| Brocade | Silkworm 2400/2800(仅用于 TapeSAN) |
| Brocade | Silkworm 3200/3250/3800/3850/3900/4100/12000/24000 |
| McData | ES 3016/3032 |
| McData | Intrepid 6064/6140/ED 5000 |
| McData | Sphereon 3216/3232/4500 |
| Cisco | MDS 9120、9140、9216A、9216i、9506、9509 |
1.8、存储子系统规格
|
存储子系统规格 |
|
|
磁盘驱动器存储架 |
DiskShelf14 系列 - DS14、DS14mk2 FC 和 DS14mk2AT;每个存储架均带有 14 个 FC 和 SATA 磁盘驱动器专用短插槽 |
| 磁盘驱动器存储架接口 | 基于 PCI 的光纤通道仲裁环路 (FC-AL) |
| DiskShelf14 接口 | 双冗余回路阻抗电路 (LRC) 模块或者冗余电子交换集线器(ESH 和 ESH2)模块 |
| 电源/散热风扇 | 可热插拔的双组冗余集成电源/风扇 (220V/110V) |
| 交流电源/最大电流 | 100 至 120 VAC/4.4A;200 至 240 VAC/2.3A |
| 工作温度和相对湿度 | 10°C 到 40°C(50°F 至 104°F);相对湿度 10% 到 95%,非凝结 |
| 存放温度和相对湿度 | -40°C 到 65°C(-40°F 至 149°F);相对湿度 10% 到 95%,非凝结 |
| 额定散热量 | 1,215 Btu/hr(机架满载情况下) |
| 工作噪声 | 23°C 时距离 1m 处 49 dBA |
| 尺寸(高/宽/深) | 3U EIA (5.25″, 13.3 cm)/可安装在 19″ IEC 机架上(17.6″,44.7 cm)/20″ (50.85 cm) |
| 重量 | 满载情况下 77 lb (35 kg) |
1.9、NETAPP系统机柜
|
NetApp 系统机柜 |
|
|
包含两组双 16A、Zero U 型配电架 (PDU) |
可以容纳 1 系统控制器和 13 个磁盘架,或者可以容纳 2 系统控制器和 12 个磁盘架,或者仅容纳 14 个磁盘架 |
| 交流电源 | 200 至 240VAC |
| 电流 | 总共 32A - 带有 NEMA L6-20 或 IEC 309 或 Australia AS/NZ53123-20 插头的两组冗余双 16A 电缆;或者总共 24A - 带有 NEMA L6-30 或 IEC 309 插头的两个冗余 24A 电缆。 |
| 尺寸(高/宽/深) | 78.75″ (200 cm)/23.6″ (60 cm)/37.4″ (95 cm) |
| 最小间隙 | 前后各 48″ (122 cm) |
| 运输高度 | 90.6″ (230 cm) |
| 重量(空载) | 275 lb (125 kg) |
1.10、法规
|
法规 |
NetApp FAS3000 系列存储设备,DiskShelf14 |
|
Filer 安全性 |
EN 60950:2002、CE、CSA 60950 和 NRTL (UL) CB(各种类似国家标准)、EN60825-1:1994、IRAM、GOST-R |
| 磁盘架安全性 | UL/C-UL;CE |
| 辐射 | FCC Class A、EN 55022:1998、EN 61000-3-2、EN 61000-3-3、CE、BSMI、AS/NZ 3548、VCCI |
| 抗扰度 | EN 55024:1998 |
1.11、对FAS3000系统磁带机的支持
|
FAS3000 系列磁带机的支持 |
|
|
合格的磁带设备 |
接口 |
|
Exabyte 8900 (Mammoth-1)、Mammoth-2 |
LVD SCSI. |
| HP Ultrium (LTO) | LVD SCSI |
| IBM 3590B、3590E | FC |
| IBM ULT3580-TDI (LTO) Ultrium-TDI (LTO) | LVD SCSI 或 FC |
| Quantum DLT 7000 | SE SCSI |
| Quantum DLT 8000、DLT-1、SDLT 220、SDLT 320 | LVD SCSI SCSI |
| Seagate Ultrium (LTO) | LVD SCSI |
| Sony AIT-1、AIT-2、AIT-3 | LVD SCSI |
| Sony GY 8240 (DTF2) | FC |
| STK 9840、9840B、9940 | FC |
FC = 光纤通道;LVD = 低压差分;SE = 单端;SE 和 LVD 不能在适配器上混用。
- We’re a little late breaking on this, but regret can stick around. If you’ve got something from 2007 you wish you could take back, you’re not alone. Wired Magazine’s foot-in-mouth awards for the year gone by.
- Edible eyes. Why? Why not!
- In bad news, Dublin’s free citywide wifi plan got squished. San Francisco residents are having much better luck. But read those comments–all’s not perfect. (Is it ever?)
- If you’re already thinking of Valentine’s gifts, how about a music-playing, leopard print Taser for the one you love? Read about some of the other oddballs items at the Consumer Electronics Show.
- MTV News ponders the future of artists who embrace Radiohead’s pay-what-you-want plan.